TL: LIMITATIONS OF HISTORIC AND CURRENT METHODS FOR MEASURING POLYCHLORINATED DIOXINS AND FURANS IN INCINERATOR EMISSIONS SO: Pat Costner, GREENPEACE INTERNATIONAL, (GP) DT: 11 MAY 1993D Methods currently used for measuring the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) in stack gases of incinerators and other combustion devices may reflect no more than 21-26 percent of the PCDD/PCDFs actually present in such stack emissions. I.e., actual emissions of PCDD/PCDFs may be 4-5 times higher than those measured by USEPA's MM5 and M23 procedures. U.S. EPA Modified Method 5 - MM5 (Coates, 1990) In their 1990 report, "Validation of Emission Test Method for PCDDs and PCDFs," USEPA examined the precision and accuracy of the Modified Method Five (MM5) sampling and analysis scheme for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/ PCDFs) in municipal waste combustor stack gas. The MM5 is also the designated method for assessing the PCDD/PCDF concentrations in the emissions of other point-sources, including hazardous waste incinerators, cement kilns, and medical waste incinerators. In their assessment of MM5, USEPA scientists measured the recovery of statically and dynamically spiked PCDD/PCDF congeners. For dynamic spiking, a system was designed that continuously delivers isotopic PCDD/PCDF congeners into the sampling train during sampling of actual incinerator stack gas. In the laboratory, recoveries of dynamically spiked PCDD/PCDFs ranged from 50% to 99% for the low spike (5 nanograms) and from 69% to 97% for the high spike (500 nanograms). However, at the full-scale incinerator, "recovery of the dynamic spikes had an overall average of 21% and were moderately variable." In this study, USEPA also investigated methods for improving spike recoveries and, hence, the overall accuracy and precision of MM5. For example, by extracting sample filters with benzene rather than dichloromethane, which is specified in the method, the overall recovery of dynamically spiked isotopic PCDD/PCDFs was increased to 26%. Considerably greater improvements were noted when the back-half glassware of the MM5 sampling train was coated with a thin layer of Apiezon-L grease. At the full-scale incinerator, rinsing the Apiezon-L coated back-half glassware with toluene resulted in recoveries ranging from 62.9% to 107%, although precision was relatively poor. U.S. EPA Method 23 -- M23 (USEPA, 1991) On February 13, 1991, USEPA promulgated the final rule for the testing procedure for PCDD/PCDFs from stationary point-sources. According to the Agency, this procedure, Method 23 or simply "M23", is derived from MM5, with some changes in the quality assurance requirements and the solvents used to recover the sample. For example, the filter and solid adsorbent are extracted in the laboratory with toluene. USEPA did not incorporate into M23 those previously described changes which led to markedly higher recoveries during dynamic spiking. In other words, since the only substantive difference between MM5 and M23 is the substitution of toluene for dichloromethane, overall recovery of M23 can be expected to be at or near the 26% achieved with benzene, as discussed above. References (Coates, 1990) Coates, J.T., "Validation of Emission Test Method for PCDDs and PCDFs," EPA/600/3-90/007, U.S. Environmental Protection Agency, Research Triangle Park, NC, March 1990 (USEPA, 1991) United States Environmental Protection Agency, "Standards of Performance for New Stationary Sources; Addition of Methods for Measurement of Polychlorinated Dibenzo-p-Dioxins, Polychlorinated Dibenzofurans, and Hydrogen Chloride Emissions From Stationary Sources," Federal Register, Vol. 56, No. 30, Wednesday, February 13, 1991, pp. 5758-5775